SURFACE
APPLIED DETECTABLE GUIDANCE TILE
SECTION 09305
PART 1 GENERAL
- related documents
- Drawings and general provisions
of Contract, including General and Special Conditions and
Division 1 Specifications Section, apply to this Section.
B. DESCRIPTION
- This Section specifies furnishing
and installing surface applied Detectable Guidance Tiles
where indicated.
- SUBMITTALS
- Product Data: Submit manufacturer’s
literature describing products, installation procedures
and routine maintenance.
- Samples for Verification
Purposes: Submit three (3) samples of full size surface
applied detectable directional bar tiles of the kind proposed
for use.
- Shop drawings are required
for products specified showing fabrication details; tile
surface profile; structural flange locations; plans of tile
placement including joints, and material to be used as well
as outlining installation materials and procedure.
- Material Test Reports: Submit
test reports from qualified independent testing laboratory
indicating that materials proposed for use are in compliance
with requirements and meet the properties indicated.
- Maintenance Instructions:
Submit copies of manufacturer’s specified maintenance practices
for each type of tile and accessory as required.
- The manufacturer shall provide
a list of projects in California that successfully demonstrate
the products durability and weatherability.
- QUALITY ASSURANCE
A. Provide
surface applied Detectable Guidance Tiles as produced
by a single manufacturer. The manufacturer shall have
a minimum of two (2) years experience in the manufacture
of Detectable Directional Bar Tiles.
- Installer’s Qualifications:
Engage an experienced Installer certified in writing by
tactile manufacturer as qualified for installation, who
has successfully completed tile installations similar in
material, design, and extent to that indicated for Project.
Manufacturer’s supervisor shall be present at all times
during the installation of the Detectable Directional Bar
Tiles.
- Vitrified Polymer
Composite (VPC) Detectable Directional Bar Tiles shall be
an epoxy polymer composition employing aluminum oxide particles
in the raised surface.
- Water Absorption of Tile
when tested by ASTM-D 570 not to exceed 0.35%.
- Slip Resistance of Tile
when tested by ASTM-C 1028 the combined wet/dry static
co-efficient of friction not to be less than 0.80.
- Compressive Strength of
tile when tested by ASTM-D 695-91 not to be less than
18,000 psi.
- Tensile Strength of Tile
when tested by ASTM-D 638-91 not to be less than 10,000
psi.
- Flexural Strength of Tile
when tested by ASTM - C293-94 not to be less than 24,000
psi.
- Gardner Impact to geometry
"GE" of the standard when tested by ASTM-D 5420-93
to have a mean failure energy expressed as a function
of specimen thickness of not less than 450 in. lbf/in.
A failure is noted if a hairline fracture is visible in
the specimen
- Chemical Stain Resistance
of Tile when tested by ASTM-D 543-87 to withstand without
discoloration or staining - 1% hydrochloric acid, urine,
calcium chloride, stamp pad ink, gum and red aerosol paint..
- Abrasive Wear of Tile when
tested by BYK - Gardner Tester ASTM-D 2486* with reciprocating
linear motion of 37 ± cycles per minute over a 10"
travel. The abrasive medium, a 40 grit Norton Metallite
sand paper, was fixed and leveled to a holder. The combined
mass of the sled, weight and wood block is 3.2 lb. Average
wear depth shall not exceed 0.030 after 1000 abrasion
cycles measured on the top surface of the dome representing
the average of three measurement locations per sample.
- Fire Resistance:
When tested to ASTM E84 flame spread shall be less than
25.
- Accelerated Weathering
of Tile when tested by ASTM-G26-95 for 2000 hours shall
exhibit the following result - no deterioration, fading
or chalking of surface of tile.
- Vitrified Polymer Composite
(VPC) Detectable Guidance Tiles adhered to concrete shall
meet or exceed the following test criteria:
- Accelerated Aging and Freeze
Thaw Test of Tile and Adhesive System when tested to ASTM-D
1037 shall show no evidence of cracking, delamination,
warpage, checking, blistering, color change, loosening
of tiles or other defects.
- Salt and Spray Performance
of Tile and Adhesive System when tested to ASTM-B 117
not to show any deterioration or other defects after 100
hours of exposure.
- DELIVERY, STORAGE AND
HANDLING
- Tiles shall be suitably packaged
or crated to prevent damage in shipment or handling. Finished
surfaces shall be protected by sturdy wrappings, and tile
type shall be identified by part number.
- Tiles shall be delivered
to location at building site for storage prior to installation.
6. SITE CONDITIONS
- Environmental Conditions
and Protection: Maintain minimum temperature of 40 degrees
F in spaces to receive tactile tiles for at least 48 hours
prior to installations, during installation, and for not
less than 48 hours after installation. Store tactile tiles
material in spaces where they will be installed for at least
48 hours before beginning installation. Subsequently, maintain
minimum temperature of 40 degrees F in areas where work
is completed.
- The use of water for work,
cleaning or dust control, etc. shall be in contained and
controlled and shall not be allowed to come into contact
with the passengers or public. Provide barricades or screens
to protect passengers or public.
- Disposal of any liquids or
other materials of possible contamination shall be made
in accordance with federal state and local laws and ordinances.
- Cleaning materials shall
have code acceptable low VOC solvent content and low flammability
if used on the site.
- Contractor shall coordinate
phasing and flagging personnel operations as specified elsewhere.
- EXTRA STOCK
- Deliver extra stock to warehouse
designated by the engineer. Furnish new materials from same
manufactured lot as materials installed and enclose in protective
packaging with appropriate identification. Furnish not less
than two (2)% of the supplied materials for each type, color
and pattern installed.
- GUARANTEE
- Surface applied detectable
directional bar tiles shall be guaranteed in writing for
a period of five years from date of final completion. The
guarantee includes defective work, breakage, deformation,
fading and chalking of finishes, and loosening of panels.
Part 2 PRODUCTS
- MANUFACTURERS
- Available Manufacturers:
Subject to compliance with requirements, manufacturers offering
products that may be incorporated in the Work include, but
are not limited to, the following:
- The Vitrified Polymer Composite
(VPC) Surface Applied Detectable Guidance Tiles specified
is based on Armor-Tile manufactured by Engineered Plastics
Inc. (800-682-2525).
- MATERIALS
- Heavy duty elastomeric polyurethane
adhesive as manufactured by Boiardi, Mapei, Bostik or approved
equal.
- Heavy duty elastomeric polyurethane
sealant as manufactured by Boiardi, Mapei, Bostik or approved
equal.
PART 3 EXECUTION
- INSTALLATION
- During all surface preparation
and tile installation procedures ensure adequate safety
guidelines are in place and that they are in accordance
with the applicable industry and government standards.
- The application of all adhesives
and sealants shall be in strict accordance with the guidelines
set by their respective manufacturers.
- Throughout the installation
phases of surface preparation and tile setting, ensure that
care is taken to prevent damage to any work.
- Lay out area to receive tile
and mark with an indelible felt pen a reference grid for
the tile to be laid.
- Set the diamond bladed double
headed wet saw to the appropriate depth of 1 ½ " x
¼" wide to achieve the necessary parallel grooves in
the area to receive the Detectable Guidance Tile.
- After saw cutting has been
completed, the surface is to be vacuumed and power washed
with clean clear water, free from all dirt and debris. Visually
inspect all surfaces for obtrusions or foreign matter. If
obtrusions are present, promptly grind away.
- Immediately prior to installing
the surface applied Detectable Guidance Tiles, all surfaces
must be inspected to ensure that they are clean, dry, free
of voids, curing compounds, projections, loose material,
dust, oils, grease, sealers and determined to be structurally
sound before the application of the setting adhesive. The
setting adhesive requires that the substrate and the ambient
temperature are 40 degrees F minimum.
- Spread the adhesive to provide
complete coverage in the grooves and over the surface, using
a clean, well-maintained ¼ " x ¼ " V notch trowel.
- Inspect the tile and clean
with acetone all dust and other contaminants from the surfaces
to be adhered, then set the tile in place, true and square
- All subsequent tiles are
set following the same procedures as outlined in H and I.
A gap of 3/16" allowed between tiles for expansion
and contraction is mandatory.
- Following the installation
of the tiles, the urethane sealant system color matched
to the adjacent surface should be applied to the joint between
abutting tiles and between tiles and adjacent surface. Follow
the manufacturer’s recommendations when mixing or applying
the sealant system and ensure that the joint is clean and
free of debris, and any excess adhesive is cut away to provide
sufficient depth for the sealant in the saw cut in accordance
with the contract drawings.
- After the area has been fully
tiled and sealant system applied, the tile surface shall
be cleaned, following the recommended maintenance and cleaning
procedures.
- CLEANING AND PROTECTING
- Protect tiles against damage
during construction period to comply with guidance tile
manufacturer’s specification.
- Clean guidance tiles not
more than four days prior to date scheduled for inspection
intended to establish date of substantial completion in
each area of project. Clean tile by the method specified
by the manufacturer.
--- End of Section
---
|